Injection Point Corrosion - Corrosion Inspection
- Chemical and Process injection without proper control has been responsible for significant industry incidents.
- American Petroleum Institute (API 570) mandates enhanced inspections of specific locations downstream of the injections.
- Rightrax, non-destructive testing (NDT) permanently mounted sensors can be installed though these locations and provide continuous thickness and profile readings in these locations.
- System installation can be responsive to process change without deploying personnel resulting in increased data integrity at reduced costs.
![]() |
![]() |
| Rightrax sensors can be applied directly over an injection point area of concern and provide continuous wall thickness monitoring | Loss of wall thickness due to injection point corrosion |