Sampling Systems for Gas & Moisture Analyzers

Sampling Systems for Gas & Moisture Analyzers

Sample handling systems are essential for getting top performance from your gas and moisture analyzer systems. To get the right sample system for your unique application, turn to GE, the analyzer application expert with more than 40 years of design and construction experience. Couple GE moisture and gas analyzers with off-the-shelf or custom-designed GE sample handling and you’ve got a reliable, accurate, and lowmaintenance measurement system.

 

GE sample systems enhance the performance of an analyzer by providing sample gas to the analyzer at optimal pressure, temperature, flow rate, and cleanliness. Designed specifically for hazardous environments and for use with GE analyzers, GE sample handling systems reduce your cost and downtime by:

 

• Providing better accuracy and reliability of measurement
• Extending analyzer life
• Limiting analyzer maintenance and associated parts and labor
• Facilitating field calibration

Contact Sales

final_phone2

Get the Moisture
Calculator iPhone app.

Standard

  • ss01b


    Trace Moisture Sample System for Instrument/Plant Air

  • ss04a


    Trace Moisture Sample System for Furnace Gases

  • ss05a


    Trace Moisture Sample System for Natural Gas

  • ss09a


    Trace Sample System for Moisture in Hydrocarbon Gases

  • ss01b


    Trace Sample System for Moisture Hydrogen-Cooled Generators

  • ss04a


    Trace Purged Sample System for Moisture in Corrosive Applications

  • ss05a


    Sample System for LEL Oxygen in Low Pressure Inerting Gas Applications

  • ss09a


    O2X1 Sample System for oxygen with PSDA Display

  • ss51c


    Trace Moisture Sample System for Low-Temperature Hydrocarbon Liquids

  • ss52b


    PFA sample system for H2 in chlorine measurement

  • ss81b


    Dual coalescer sample systems for moisture analysis for natural gas with high concentration glycol carryover

  • ss880


    Percent oxygen sample system with Auto calibration for waste water treatment plant bio-reactor headspace application

Custom

  • link-b_dsc00038

    Percent oxygen sample system with auto calibration for waste water treatment plant bio-reactor headspace application

  • b_h2incl2

    PFA sample system for H2 in chlorine measurement

  • b_inland

    Trace moisture, oxygen and percent hydrogen system for 8 zones of measurement in an annealing furnace

  • b_sampsyst

    Dual coalescer sample systems for moisture analysis for natural gas with high concentration glycol carryover

Applications

Our application and service engineering teams possess the expertise to provide a comprehensive sample system designed and built for your specific situation. We know how our analyzers perform in various applications and how our sample handling systems can help deliver the best measurements. We offer a cost-effective source for complete analyzer packages.

  • Standard systems for common applications
  • Engineered systems for customer-specific requirements
  • Design, construction, and inspection of all systems
  • Installation guidance
  • Start-up and commissioning
  • Calibration
  • Extended warranties and service plans for analyzer systems

Specifications

Wetted Materials Typically 304SS, 316SS, or 316LSS. Components may have glass, viton o-rings, or other wetted materials. Systems
available in Monel and/or 316SS for NACE MR1075 EN3.1.B compliance for natural gas streams with high H2S content.
Sample systems can also be manufactured with PFA tubing and components for acid gas applications.
Isolation Via needle and/or ball valves
Pressure Regulation Via pressure regulators and/or back-pressure regulators. Systems can be supplied with pumps or eductors to pull a gas
sample from a low pressure source.
Temperature Control Enclosed sample panel with insulation may be heated by enclosure heaters (typically explosion-proof) and/or cooled by
air handling systems or vortex coolers, both with thermostat control. Systems in direct sunlight environments may use a
sunshade to avoid radiational heating.
Heat tracing of sample lines from sample tap to sample system panel is within the customer or contractor scope.
Flow Control and Measurement Via needle valves and/or fine metering valves. Displayed measurement via variable area (VA) flowmeters. Alarms via
integral flow switches on VA flowmeters or via separate flow switch component.
Fittings Typically compression type fittings, 1/4 in (6 mm). Custom systems available with VCR® installations for UHP applications
requiring metal-to-metal face sealing components.
Filtration Particulate filtration typical to 7 micron particulate level. Liquid knock-out via coalescing filters, membrane filters, and liquid
dumps.
New Sampling/Sensor Initiative (NeSSITM) Systems available designed to NeSSI (ISA SP76) for certain products.
Quality Assurance GE sample systems are designed and manufactured in accordance with manufacturing site quality policies (typically ISO 9001) and using GE application engineering standard practices. All sample systems are visually inspected for workmanship and to conformance-to-order requirements.
Sample systems may also be inspected against standard drawings or customer-approved drawings, where applicable. All sample systems are pressure tested using dry compressed air and leak detection fluid.
Documentation GE can provide sample system drawings as quoted/built. For complicated projects, an approval cycle is recommended and
system sub-sourcing and construction is typically initiated after receipt of approved drawings. Typical drawing packages include one CAD 2-D outline and dimension drawing with component layout/interconnections plus a BOM (Bill of Material) for each unique sample system design in a particular order.
Factory Acceptance Test (FAT) GE can perform FATs at our manufacturing sites to accommodate customer-specific inspection requirements such as visual inspection, pressure/leak testing, operational performance test, and documentation inspection. FAT requires GE review and acceptance of customer requirements, which usually is done at the inquiry and quotation stage.