Print

PanaFlow Z3 Ultrasonic Liquid Flow Meter

PanaFlow Z3

The PanaFlow Z3 is the latest of a new generation of Panametrics ultrasonic flow meters. It is a three-path wetted meter designed specifically for low-risk, accurate and repeatable measurement of nominal temperature liquids. With a sleek industrial design and ultra-reliable electronics, it provides a top-of-the-line choice for process and industrial applications.

High-end design

The Z3’s integrated flow cell encloses the transducers, buffers, junction boxes and cables, making it not just an aesthetic design, but a rugged, compact and easy-to-handle meter. Transducers are removable in the field, allowing for replacement without shutting down the process. New design Vitality software is completely intuitive and easy to use.

Advanced performance

Three-path technology gives better accuracy and allows for more visibility of the flow profile. It also offers an extra path for peace-of-mind redundancy. New XMT910 electronics, designed for ultra reliability, communicate seamlessly in HART® or Modbus protocol.

Low cost of ownership

Ultrasonic flow meters help take care of your assets without the maintenance required with other, non-ultrasonic types of flow meters. Hours saved on maintenance, installation and calibration translate directly to the bottom line. With ultrasonic flow measurement there is no drifting, no pressure drop, no restriction in the pipe and no moving parts---nothing to impact the process or damage the meter.

PanaFlow Z3 Information

  • New, highly reliable electronics
  • Cast flowcell with aesthetic industrial look
  • Three-path design for accuracy and redundancy
  • Field replaceable transducers for easy maintenance
  • No extended buffers
  • No certified junction boxes
  • No external cables

Customers

  • Upstream, midstream and downstream oil and gas
  • Chemical
  • Petrochemical

Applications

  • Process control and monitoring
  • Allocation measurement
  • Batching and blending lines
  • Transfer lines
  • Cooling water lines

 

Operation and Performance

Fluid Types
  • Acoustically conductive fluids, including most clean liquids, and many liquids with small amounts of entrained solids or gas bubbles
Flow Measurement
  • Patented Correlation Transit-TimeTM model
Accuracy
  • ±0.5% of reading for velocities above 1.6 ft/s (0.5 m/s)
  • ±2.5 mm/s of reading for velocities below 1.6 ft/s (0.5 m/s)

Accuracy statement assumes measurement of a single-phase homogenous liquid with a fully developed symmetrical flow profile passing through the meter. Applications with piping arrangements that create an asymmetrical flow profile may require extended piping straight runs and/or flow conditioning for the meter to perform to this specification.

Calibration
  • All meters are calibrated and include a calibration certificate.
Repeatability
  • ±0.2% of reading
Range (Bidirectional)
  • -40 to 40 ft/s (-12.19 to 12.19 m/s)

 

Meter Body/Transducers

Meter Body Materials
  • CS: ASTM SA216 Gr. WCB
  • SS: ASTM SA351 Gr. CF8M
Transducer System Materials
  • LX transducers with inserts (patent pending): 316L SS
  • Seals: FKM or EPDM
Transducer Temperature Ranges
  • -4°F to 284°F (-20°C to 140°C)
Pressure Range
  • Up to maximum allowable flange operating pressure at temperature

 

Electronics

Enclosures
  • Epoxy coated, copper-free aluminum
Classifications (Pending)
  • US/CAN – Explosion-proof Class 1, Division 1, Groups B, C, and D
  • ATEX - Flameproof II 2 G Ex d IIC T6 Gb
  • IECEx - Flameproof Ex d IIC T6 Gb
  • Exempted from ROHS compliance (Category 9)
  • WEEE Compliance
Electronics Mounting
  • Local mounting (on meter body)
Channels
  • Three channels
Paths
  • Three paths
Display Languages
  • English
Keypad
  • Built-in magnetic six-button keypad for full functionality operation
Inputs/Outputs
  • One analog (4-20mA+HART®) output, one additional analog (4-20mA) output, two digital* outputs, service/Modbus (RS485) output

*Digital outputs are programmable as either pulse, frequency, alarm, or control outputs.Analog outputs are NAMUR NE43-compliant.

Power Supplies
  • Standard: 100 to 240 VAC (50/60 Hz)
  • Optional: 12 to 28 VDC
Cable Entries
  • ¾ in NPT
  • M20
Operating Temperature
  • -40°F to 140°F (-40°C to +60°C)
Storage Temperature
  • -40°F to 158°F (–40°C to 70°C)
Data Logging
  • XMT910 meter logging (3000 variables)
  • Vitality software logging

 
Descriptions English
FM ATEX Certification FM ATEX Certification
FM Can Certification FM Can Certification
FM IECEx Certification FM IECEx Certification
FM US Certification FM US Certification
PanaFlow Z3 Brochure PanaFlow Z3 Brochure
PanaFlow Z3 Datasheet PanaFlow Z3 Datasheet
PanaFlow Z3 User Manual PanaFlow Z3 User Manual


acrobat-reader