T6500 CO2 Module

T6500 CO2 Module

The Telaire® 6500 series module is a low-cost CO2 threshold sensor designed to meet the volume, cost, and delivery expectations of Original Equipment Manufacturers (OEM). The module is ideal for customers who are familiar with the design, integration, and handling of electronic components but do not wish to invest resources in their own development effort.

 

 

 

 

 

Features

  • Designed specifically for the Original Equipment Manufacturer (OEM).
  • Reliable design based on 15 years of low-cost infrared sensor manufacturing.
  • Affordable technology
  • Low power consumption
  • RoHS and WEEE compliant for European applications.

Applications

When used in a building monitoring system, the T6500 dual sensor module allows building owners and managers to quickly,easily and efficiently moniotr the building air quality to stay within regulation.

Specifications

General Performance

Operating Temperature Range 41°F to 86°F (5°C to 30°C)
Storage Temperature Range -4°F to 140°F (-20°C to 60°C)
Operating Humidity Range 20 to 100% non-condensing

Compliance with

T6500-tb-1

Electrical (Default Settings)

Power Input
  • Regulated Voltage Supply: 5V ±10%
  • Battery Supply: 4.3 VDC – 7.0 VDC
Average Current
  • 2 minute sampling rate < 2.4 mA per hour ave, typical
  • 10 second sampling rate < 13.0 mA per hour ave, typical
Peak Current < 90 mA ±10% (94 – 95 mA default/typical)
Low Voltage Shut-down 4.3 VDC ±5%
Connector (5-pin)
  • *Pin 1 → Adjustable: CO2 Threshold #1 (0.8% 8000 ppm default/typical)
  • *Pin 2 → Adjustable: Battery Threshold (5.3V default/typical)
  • Pin 3 → V+
  • Pin 4 → V-
  • Pin 5 → Adjustable: CO2 Threshold #2 (0.9% 9000ppm default/typical)
Connector Type JST B5B-EH-A(LF)
Reverse Polarity Protection
None

Measurement Accuracy (Default Settings)

Threshold Setpoint *0.9% CO2 in air ± .1% CO2 by volume
Threshold Hysteresis *0.1% CO2 by volume
*0.1% CO2 by volume
  • *2 minutes < 7000 ppm
  • *10 seconds > 7000ppm
Number of samples
  • *3 Consecutive above 0.9% CO2 for threshold
  • *3 Consecutive below 4.3 V for low battery threshold
Note: “*” denotes customizable feature.
Printed Circuit Board Dimensions
  • Mounting Holes: The sensor board shall have (4) mounting holes to mate with standard circuit board locking stand-offs.
  • Hole diameter = 4 mm (0.2, -0.0 mm).
  • Clearance diameter for stand-off = 0.20 in (5.2 mm)