GE Measurement & Control SolutionsGE Measurement & Control

Home » Test & Calibration Equipment » Test, Simulation & Calibration » TK-3 Proximity Probe Calibration Instrument
E-mail Print

TK-3 Proximity Probe Calibration Instrument

Proximity Probe Calibration

This portable instrument is used for both static and dynamic verification of proximity probes. The TK3, commonly referred to as the Wobulator™ , verifies the operating condition of the monitor readouts as well as the condition of the proximity transducer system. A properly calibrated system ensures that the transducer inputs and resulting monitor readings are accurate. New features include a universal probe mount that will accommodate probe diameter from 5 to 19 mm, a more rugged case, increased reliability, and a convenient magnetic mountable spindle micrometer.

Contact Sales

 

 

 

 

Specifications

Power Requirements

Electric: 95-125 Vac, 50/60 Hz, 1A minimum 190-250 Vac, 50/60 Hz, 1A minimum
Air: 90 psi (6.2 bar) maximum

Wobulator Range

Vibration Amplitude Range: 50 μm to 254 μm (2 to 10 mils) peak-to-peak.

Maximum Speed

Electric: 0 to 5000 cpm ± 1000 cpm
Air: 0 to 5000 cpm ± 1000 cpm
Spindle Micrometer Range: 0 – 25.4 mm (0 – 1000 mils).
Target Button and Wobble Plate: AISI 4140 Alloy Steel.
NOTE: Contact your nearest Sales Professional for details on special target and wobble plate materials.

Physical Size

Height: 195 mm (7.68 inches)
Width: 299 mm (11.8 inches)
Depth: 248 mm (9.76 inches)
Weight: 5.22 kg (11.5 lb)

Environmental

Operational Temperature Range 0 °C to 54 °C (32 °F to 130 °F)
Storage Temperature Range -18 °C to 65 °C (0 °F to 150 °F)
Humidity 95% Non-Condensing Humidity
Exposure Designed to meet IP54 for dust and water exposure (closed)

CE Mark Directives

EMC Directives 2004/108/EC – with amendments
IEC/EN61000-6-2
Electrostatic Discharge EN61000-4-2 Criteria A
Electro-Magnetic Field (Radiated Immunity) EN61000-4-3 Criteria A
Electrical Fast Transient Burst EN61000-4-4 AC Power Cable, Criteria B Line to Ground, Criteria B Neutral to Ground, Criteria B Protective Earth to Ground, Criteria B Line/Neutral/Protective Earth to Gnd, Criteria B
Surge Capability EN61000-4-5 AC Power Ports, Criteria A
Conducted Immunity EN61000-4-6
AC Power, Criteria A
Voltage Dips and Interrupts EN61000-4-11
40%, 10 Cycles (200 mS) Criteria A
70%, 25 Cycles (500 mS) Criteria C
0%, 250 Cycles (5 Sec), Criteria C
IEC/EN61000-6-4 Radiated Emissions
EN61000-6-4
Conducted Emissions EN61000-6-4
Low Voltage Directive IEC/EN 61010-1

Download


Descriptions English
ORBIT TK-3 Proximity Probe Calibration Instrument acrobat-reader
TK-3 Proximity Probe Calibration Instrument Datasheet acrobat-reader


acrobat-reader