Print

200132 Pressure Transducer

Static Pressure Transducer

The 200132 pressure transducer is intended for general purpose, static pressure measurements made with our Trendmaster® Pro data acquisition hardware. It interfaces to the 200130 flexiTIM, features robust, stainless steel construction, and is available in a variety of pressure ranges.

 

 

 

 

 

 

 

All specifications are at 25 °C (77 °F) unless otherwise specified.

Operation outside the specified limits will result in false or inaccurate readings.

200130 Dual Pressure flexiTIM

Electrical

Full Scale Range The pressure transducer sets the Trendmaster full-scale pressure range. The user enters the transducer's full-scale range into the Trendmaster software.
Accuracy ±8.5% of the transducer full-scale rating (transducer accuracy not included).
Transducer Excitation Voltage 4.98 Vdc ± 65 mVdc
Maximum Transducer Supply Current 2.5 mA absolute maximum available over temperature
Transducer OK Range 1 Vdc to 3 Vdc bias from transducer (nominal).
Resolution 0.025% of transducer's full scale rating.
Transducer Bridge type meeting stated requirements

Environmental Limits

Operating Temperature -40 °C to +100 °C (-40 °F to +212 °F).
Humidity 100% condensing on exposed surfaces.
100% non-condensing on surfaces inside conduit.
Enclosure Type NEMA Type 4 ( ?)

Mechanical

Housing Materials Powder-coated aluminum
Weight 554 g (20 oz) not including conduit body
Dimensions See Figure 1 and Figure 2.

Electromagnetic Compatibility

Radiated Emissions EN 55022 (1994). Class A.
Electrostatic Discharge EN 61000-4-2 (1995), Criteria A
Radiated Susceptibility EN 61000-4-3 (1997) (ENV 50140 : 1993), Criteria A.
Conducted Susceptibility ENV 50141 (1993), Criteria A
Electrical Fast Transient EN 61000-4-4 (1995), Criteria A
Surge Capability ENV 50142 (1994), Criteria A
Magnetic Field EN 61000-4-8 (1994), Criteria A

Hazardous Area Approvals
CSA

Installed with Intrinsically Safe Zener Barriers per Drawing 136925 Class I, Div 1 Groups A, B, C & D
Class II, Div 1 Groups E, F & G
Class III, Div 1
Ex ia IIC; T4, Ta = 100 °C
Class I, Zone 0
Installed Without Barriers per Drawing 136926 Ex nA IIC, Class I, Zone 2
T4, Ta = 100 °C
Class I, Div 2, Groups A, B, C & D
T4, Ta = 100 °C

CENELEC

Installed with Intrinsically Safe Zener Barriers per Drawing 136925 Ex II 1 G
EEx ia IIC T4, Ta = 100 °C
LCIE 99 ATEX 6001X

200131 Cables

Operating Temperature -20 °C to +100 °C (-4 °F to +212 °F).
Minimum Bend Radius 25.4 mm (1.0 in)
Construction 4-conductor (22 AWG) with foil shield and drain wire (100% coverage), yellow PVC outer jacket
Connectors Screw-on, 5-pin, keyed connector on the flexiTIM end and a PT06F8-4S (or equivalent) on the transducer end. The user should install the environmental boot over the transducer’s connector and body.

200132 Pressure Transducer

Pressure Ranges PSI SG 30, 50, 100, 300, and 500
Sensitivity 10 mV/V ± 1%
Zero Offset ±3mV (±6% of full scale range) at atmospheric pressure (14.7 PSI)
Absolute Accuracy ±4% over compensated temperature range
Excitation 5 Vdc to 10 VDC (nominal)
Input Resistance > 2 K Ω
Output Resistance < 6 K Ω
Operating Temperature -54 °C to +121 °C (-65 °F to +250 °F).
Compensated Temperature +10 °C to +93 °C (+50 °F to +200 °F).
Connector MS3113H8-4P, 4-position male or equivalent:
A = + Excitation
B = + Out
C = - Out
D = - Excitation
Proof Pressure 2X Full Pressure Scale
Burst Pressure 3X Full Pressure Scale
Pressure Fitting 1/4 - 18 NPT male
Case Material 316 Stainless Steel.
Insulation resistance > 50 MΩ @ 50 VDC.

press-trans-1


Descriptions English
200132 Pressure Transducer Datasheet 200132 Pressure Transducer Datasheet


acrobat-reader