Some valve position measurements incorporate a linear, rather than rotary, mechanical linkage. Our AC LVDT is designed for such applications and is available in ranges from 1.0 to 28.0 inches (25 to 703 mm).

 

 

 

 

Contact Sales

 

 

 

 

Specifications

Electrical

Linearity 0.25% of full-scale
Null Voltage 0.5% of full-scale, maximum

Environmental Limits

Operating Temperature -54 °C to +149 °C (-65 °F to +300 °F)

Mechanical

Height 50.8 mm (2.0 in)
Option -04 has a height of 69 mm (2.7 in)
Width 31.8 mm (1.25 in)
Option -04 has a height of 50.8 mm (2.0 in)
Length 18639-01: 165 mm (6.50 in)
18639-02: 194 mm (7.64 in)
18639-04: 546 mm (21.5 in)
18639-05: 280 mm (11.01 in)
18639-06: 352 mm (13.85 in)
18639-07: 481 mm (18.92 in)
18639-08: 810 mm (31.9 in)
18639-09: 424 mm (16.7 in)
Weight Typically, 1.1 kg (2.4 lb)