ADTS 505 - Air Data Test Set

ADTS 505 - Air Data Test Set

The ADTS 505 is the latest in a series of reliable, compact and high accuracy Air Data Test Sets.The flightline design has evolved as a result of GE Infrastructure Sensing continuous research and development, customer feedback and experience gained from manufacturing thousands of automatic pressure controllers. This has enabled performance, ease of maintenance and operational simplicity to be optimized.

Contact Sales

 

Features

  • High accuracy - RVSM compliant
  • Fully automatic control
  • Rugged flightline construction
  • Wide ranging aircraft compatibility
  • Integral pneumatic supplies
  • Protection for aircraft instruments

Specifications

The ADTS 505 is housed in a rugged weatherproof case, complete with internal pneumatic pumps for pressure and vacuum generation. Automatic control is implemented by simple menu instruction and keypress at the front panel.

adts-505-1

Scaling Factors Altitude: ft, meters
Airspeed: knots, km/hr, mph
Rate of Climb: ft/min, m/min, m/s, hm/s
Others: mbar, inHg, inH2O, mmHg, kPa, hPa, psi
Rate Control/Indication Roc: Rate of Climb
Rt Ps: Rate of Static
Rt Pt: Rate of Pitot
Rt Qc: Rate of Pt_Ps
Rt CAS: Rate of calibrated airspeed
Rt EPR: Rate of engine pressure ratio
Overpressure Negligible calibration change with up to 1.25 x full scale (FS) overload applied.
Calibration Stability Better than 0.005% (Ps) and 0.08% (Qc) FS per annum.
Recalibration Simple keypad instruction. 12 month interval suggested. Use of primary standard pressure reference (e.g. Ruska Primary Pitot Static Tester model 2468) is recommended.
Display Large area, 1/4 VGA, high contrast, electro-luminescent display. 96 mm x 73 mm (3.7 in x 2.8 in), 320 x 240 pixels.
Response Two readings-per-second display value update.
Power Supplies 90 to 132 VAC at 47 to -440 Hz, 180 to 265 VAC at 47 to 66Hz auto-selection
Rating 200 VA
Power Failure Protection System locks, and a manual let-down feature is provided.
Self Test Integral test routines and reporting for both electrical and pneumatic systems.
Temperature Range Calibrated: 5°C to 35°C (41°F to 95°F)
Operating: 0°C to 50°C (32°F to 122°F)
Storage: -20°C to 70°C (-4°F to 158°F)
Sealing Weatherproof in operating mode (lid removed).
Humidity 0 to 95% non-condensing. “Tropicalized” specification.
Shock/Vibration Designed to meet MIL-T-28800 Class 2.
Conformity EN61010, EN61326. CE marked.
Physical Weight 15 kg (33 lb) nominal
Dimensions (including lid): 265 mm x 520 mm x 355 mm (10.4 in x 20.5 in x 14 in)
Case ABS moulded case with removable lid and storage for accessories.
Pneumatic Connections AN4 for Ps and Pt, both color-coded.

Supplied with mating (approximately) 2 m (6 ft) long flexible hoses with AN4 fittings at one end.
Pneumatic Supplies Integral pressure and vacuum pumps capable of generating the following supply rates:

1829 m/min (6000 ft/min) into a 4 litre volume at 9144 m (30,000 ft)
300 knots/min into a 2 litre volume at 650 knots
Water/moisture content is vented automatically.
Accessories AC power lead—2 m (6 ft) length approximately. Ps and Pt hoses—2 m (6 ft) lengths approximately. Operators manual and calibration certificate also supplied as standard.
Calibration Standards Instruments manufactured by GE are calibrated against precision calibration equipment traceable to international standards.

Download


Descriptions English Deutsch Português
ADTS 505 - Air Data Test Set Brochure acrobat-reader acrobat-reader acrobat-reader
ADTS 505 - Air Data Test Set Option A acrobat-reader
ADTS 505 - Air Data Test Set Option B acrobat-reader
ADTS 505 Air Data Test Set - operating Manual acrobat-reader
ADTS 505 Ground Equipment Operating Manual acrobat-reader


acrobat-reader