GE Measurement & Control SolutionsGE Measurement & Control

Home » Moisture & Humidity » Moisture Analyzers » Moisture Monitor Series 3
E-mail Print

Moisture Monitor Series 3 - Moisture Analyzer

Moisture Monitor Series 3 - Moisture Analyzer

 

The Moisture Monitor Series 3 Analyzer (MMS 3) analyzer is a single- or dual-channel analyzer with a two-line, alphanumeric LCD for moisture, oxygen, temperature and other parameters. It is available as a battery-powered portable with data logging, making it ideal for spot sampling and storing data from one or two locations without reprogramming. It also offers built-in intrinsic safety for all sensor inputs. The MMS 3 is available in rack, bench, panel, weatherproof and explosion-proof packages.

 

A complete MMS 3 system consists of the MMS 3, a moisture probe, interconnection probe cable and an optional sample system. The MMS 3 can also use the nondepleting oxygen cell to allow oxygen measurement. 

Contact Sales

final_phone2

Get the Moisture
Calculator iPhone app.

Features

  • Absolute humidity in gases and liquids
  • Single or dual channel
  • Optional battery-powered portable
  • 12-bit moisture measurement resolution
  • Compatible with TFM Seriestype moisture probes
  • Auxiliary inputs for other parameters
  • Computer-enhanced speed of response
  • Intrinsically safe, certified to EEx ia IIC and Class I, Div. 1, All Groups

 

Applications

This Panametrics aluminum oxide moisture sensor probe measures moisture concentration in gases and non-aqueous liquids from trace to ambient levels. It is designed to be used in conjunction with all Panametrics moisture analyzers for industries including:
• Petrochemical
• Natural gas
• Industrial gas
• Semiconductor
• Furnace gas/heat treating
• Power generation
• Air dryer
• Pharmaceutical
• Aerospace

Specifications

Electronics

Intrinsic Safety Galvanic isolation and energy-limiting circuitry for all inputs (except auxiliary):
BAS01ATEX7097
II (1) G [EEx ia] IIC –20°C to 50°C;
CSA C US Class I, Division 2, Groups B,C&D T4A–Assoc.
Elec. Apparatus [Exia] and Class I, Division 1,
Groups A, B, C & D T4
European Compliance Complies with EMC Directive 89/336/EEC and 73/23/EEC LVD (Installation Category II, Pollution Degree 2)
Inputs Moisture: One or two channels
  • Temperature: One or two channels
  • Pressure: One or two channels
  • Oxygen: One or two channels
  • Auxiliary (optional): Two per installed channel; may be used for 0/4 to 20 mA and 0 to 2 V devices
Analog Outputs Two per channel; internally optically isolated; 12-bit (.025% resolution)
Programmable Switch-Selectable Outputs
  • 0 to 2 V, 10 kΩ minimum load resistance
  • 0/4 to 20 mA, 400 Ω maximum series resistance
Digital Outputs RS232 serial communications port; information is transmitted as ASCII characters
Computer-Enhanced Response Optional: Software provides fast measurements in abrupt dry-down applications (three- to five-minute speed of response)
Data Logging Up to 12 parameters simultaneously; stored in batterybacked RAM (64 kB); log length depends on number of items and time interval
Memory
  • Standard: 64 kB RAM
  • Optional: Additional 1 MB or more with PCMCIA card
PC-Interface Software Optional: PanaView™ instrument interface software
Alarm Relays
  • Two optional Form C relays per channel SPDT; rated for 2 A at 28 VAC/28 VDC
  • Standard and hermetically sealed (for Division 2 hazardous areas per CSA) available for high and low limits on each channel; set to any level within the range of the instrument
Alarm Set Point Accuracy ±0.18°F (±0.1°C) dew point
Display 2 line x 20 character backlit LCD
Display Functions Displays two parameters
Power Requirements
  • Universal power supply adjusts automatically for 90 to 260 VAC, 50/60 Hz
  • Rechargeable battery pack (optional) lasts 8 hours under normal use and fully recharges in 16 hours
Temperature
  • Operating: 32°F to 140°F (0°C to 60°C)
  • Storage: –22°F to 158°F (–30°C to 70°C)
Configuration Dimensions (h x w x d)
  • Rack mount: 5.22 in x 19.00 in x 17.03 in (13.26 cm x 48.26 cm x 43.26 cm)
  • Bench mount: 6.35 in x 8.29 in x 17.03 in (16.13 cm x 21.06 cm x 43.26 cm)
  • Panel mount: 8.25 in x 10.85 in x 17.03 in (20.96 cm x 27.56 cm x 43.26 cm)
  • Weatherproof: 22.23 in x 16.23 in x 9.48 in (56.46 cm x 41.22 cm x 24.08 cm)
  • Explosion proof: Consult factory
Add 1.65 in (4.19 cm) to accommodate strain relief tabs

Moisture Measurement

Type GE TF and M Series thin-film aluminum oxide probes
Calibration Ranges
  • Standard: 68°F to -112°F (20°C to –80°C) with data to -166°F (–110°C)
  • Ultralow: -58°F to -148°F (–50°C to –100°C) with data to -166°F (-110°C)
  • Extended high: 110°F to -112°F (60°C to –80°C) with data to -166°F (–110°C)
Accuracy (Dew/Frost Point)
  • ±3.6°F (±2°C) from 140°F to -85°F (60°C to –65°C)
  • ±5.4°F (±3°C) from -86°F to -166°F (–66°C to –110°C)
Repeatability (Dew/Frost Point)
  • ±0.9°F (±0.5°C) from 140°F to -85°F (60°C to –65°C)
  • ±1.8°F (±1.0°C) from -86°F to -166°F (–66° C to –110°C)
Operating Pressure 5 μ of Hg to 5000 psig (345 bar) limited by optional pressure sensor—see pressure sensor ranges
Other Moisture Parameters Relative humidity (RH), parts per million by volume (ppmv), parts per million by weight (ppmw), parts per billion by volume (ppbv), pounds per million standard cubic feet (lb/MMSCF)

Temperature Measurement

Type Optional thermistor built into moisture probe
Range –22°F to 158°F (–30°C to 70°C)
Accuracy ±0.9°F (±0.5°C) at -22°F (–30°C)

Pressure Measurement

Type
  • Optional transducer built into moisture probe 
  • Variety of standard GE external transmitters
  • Any user-supplied pressure transmitter, 24 V powered, 4 to 20 mA
Range 0 to 5000 psig (1 to 345 bar); specify type and pressure range
Accuracy ±1% of full scale
Pressure Rating Three times the span of the available range to a maximum of 7500 psig (518 bar)

Oxygen Measurement

Optional nondepleting electrolytic oxygen sensor. Additional details and specifications are available on request.

Download

Descriptions 中文 Dutch English Français Deutsch Italiano 日本語 Polish Português Russian Español
BASEEFA System Drawing for MMS 3 IS System acrobat-reader
Basic Hygrometry Principles acrobat-reader
M Series Moisture Probe acrobat-reader
MMS 3 Bench-Mount Package Drawing acrobat-reader
MMS 3 Interconnection Drawing for Rack, Bench & Panel acrobat-reader
MMS 3 Interconnection Drawing for Weatherproof Package acrobat-reader
MMS 3 Operating Manual acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader
MMS 3 Panel-Mount Package Drawing acrobat-reader
MMS 3 Rack-Mount Package Drawing acrobat-reader
MMS 3 Weatherproof Package Drawing acrobat-reader
MMS 35 Bench-Mount Package Drawing acrobat-reader
MMS 35 Interconnection Drawing for Bench Package acrobat-reader acrobat-reader
MMS 35 Interconnection Drawing for Rack & Panel Package acrobat-reader
MMS 35 Interconnection Drawing for Weatherproof Package acrobat-reader
MMS 35 Panel-Mount Package Drawing acrobat-reader
MMS 35 Rack-Mount Package Drawing acrobat-reader
MMS3 (w/703-1250 Controller Board) Programming acrobat-reader
MMS3 (w/703-1250 Controller Board) Quick Start acrobat-reader
MMS3 (w/703-1250 Controller Board) Service acrobat-reader
MMS3 Abridged Operating Manual acrobat-reader
MMS3 Laminated Card acrobat-reader
Moisture Monitor Series 3 Brochure acrobat-reader acrobat-reader
Moisture Monitor Series 3 Programming Manual acrobat-reader
Moisture Monitor Series 3 Quick Reference Guide acrobat-reader
Moisture Monitor Series 3 Service Manual acrobat-reader
Moisture Monitor Series 3 User Manual acrobat-reader
Moisture Target Series 6 OEM Manual acrobat-reader
Nondepleting Oxygen Cell acrobat-reader acrobat-reader acrobat-reader acrobat-reader
PanaView for MIS and MMS Series Hygrometers Operating Manual acrobat-reader
Série 3 Moisture Monitor™ Analisador de umidade da Panametrics acrobat-reader
Three-Function Moisture Probe acrobat-reader
Trace Moisture Diurnal Effects in Process Applications acrobat-reader

Click here to download MMS-3 Updates